Heat pumps use large quantities of low-grade heat energy in the ground, air or water and convert it to high-grade heat for water heating or space heating in a dwelling. The source of this heat in the UK is 99% from the sun and as long as the heat pump does not remove more energy on an annual basis than is replaced by the sun; the system will be balanced and sustainable.
The energy required to run a heat pump is a lot less than the energy generated by the heat pump and whereas the heat pump does use outside energy (electricity), if designed correctly, they have the capacity to provide a sustainable energy source at a potentially lower cost than many traditional energy sources. If the energy required to run the heat pump is also from a renewable source, then a truly sustainable heating solution is possible.
The efficiency of a heat pump is referred to as the Coefficient of Performance (COP). This is the ratio of the amount of heat energy you get for every kWh of electricity you use at a given set of circumstances (EN14511). On an air source heat pump (ASHP) the COP might be 3.2 @ A7W35. This means that at an ambient (air) temperature of 7ºC and a produced water flow temperature of 35ºC you would expect to get 3.2 kWth (kilo Watts of heat) for every kWh of electricity used. To get the best efficiency from a heat pump the heat exchangers in the refrigerant cycle must have high heat transfer rates and the temperature difference between the heat collection side (evaporator) and the heat distribution side (condenser) must be as low as possible. Therefore low flow temperatures of around 35ºC are required in the emitter circuit, which is ideal for certain under-floor heating solutions but could mean up to 7 times the surface area would be required for conventional radiators. This also means that the reaction and reheat times of the heat source are very long and therefore the heat needs to be stored in a thermal store or buffer tank and a reasonable amount of thermal mass needs to be integrated into the building to act as a heat store. In lightweight buildings the heat is stored in the air and this can be purged very quickly through ventilation losses. The heat pump controller may then detect a high load for an extended time and turn the immersion heater on for assistance resulting in an inefficient system.
The COP is quoted at a fixed set of conditions in a laboratory environment and as the conditions change so does the COP. So to get real world expectations an ‘average COP’ needs to be used that takes into account the average over a year of the useful heat produced versus the electrical input to run the heat pump, including defrost cycles and circulation pumps. This is called the Seasonal Performance Factor (SPF). “Unfortunately the SPF is very hard to standardise as it compares four variables (liquid flow rate, Temperature fluctuation through the system, heat out put and electrical consumption) that each have a margin of error, due to sensor placing and equipment calibration, that require considerable skill to measure accurately.
The Data for the Energy Savings Trust Field trials was measured in a different way from the standard SPF. Whereas heat is normally measured at the heat pump, in these trials the heat was measured going into the heating system and coming out of the hot water cylinder. This was referred to as ‘System Performance Factor’ as it gave a representation of the complete system losses. Naturally by adding more variables and more potential losses, the performance figures will be lower. This has often been mis-quoted in the industry due to the same acronyms but also by those wishing to cast a negative light on heat pumps. It must also be borne in mind that if a condensing boiler efficiency was measured in this manner, that it would fall way short of the 90%+ mark that is usually quoted for these technologies.
Most ASHPs are sized at 7ºC. An 11kW scroll compressor unit will only deliver 11kW when the ambient temperature is 7ºC. If the temperature drops to 0ºC you may only get 8kW and alternatively you may get up to 14kW when the ambient temperature is 20ºC.
Heat pumps are not ideally suited to hot water preparation, although they can achieve high temperatures albeit at an efficiency cost, and therefore need carefully sized heat exchange coils in the hot water cylinder. These will typically allow for a minimum water temperature of around 46ºC. On older heat pumps any additional heat or sanitation will need to be provided for by an immersion heater, but newer heat pumps using modern refrigerants such as R290 (propane) can potentially achieve temperatures up to around 75C. In older systems if your hot water cylinder was set to maintain a 60ºC temperature the likelihood was that the heat pump would not actually be used at all. This can often account for a significant amount of additional energy and cost. An ASHP will provide slightly lower stored water temperatures in summer than it does in winter due to the higher outputs in warmer weather across the exchange coils. There are however heat pumps that can provide a higher temperature and achieve stored water temperatures of over 60ºC albeit at a lower COP.
When comparing heat pumps with conventional forms of heating it is important to know what exactly you are comparing. The COP of a heat pump is only useful in determining efficiency when you know what the fuel is that you are displacing. As we know, the COP is a ratio of a kWh of electricity to a kWth of heat. We therefore need to establish what the kW figures are for any fuel that we may be replacing.
FUEL CALORIFIC COST CO2 kg EFFICIENCY
VALUE PER KW PER KW %
Elect: Peak 23p 0.130 100
Elect: Off peak 8p(16p) 0.50 100
Elect: Econ 7 8(18p) 0.50 100
Natural Gas 3.9p 0.183 Boiler (90+)
Oil / litre 10.4kWh 9p 0.27 Boiler (40 – 90+)
Lpg / kg 13kWh 10p 0.23 Boiler (90+)
Lpg / litre 7kWh 7.1p 0.23 Boiler (90+)
Wood: Pellets/kg 4 – 5kWh 5 – 6p 0.03
Wood: Chips/kg 3.5 - 5kWh 2.3p 0.03
Wood: Logs/kg 3.5 - 5kWh 3.5p 0.03
Costs are avarages at time of checking (August 2026). Check your own supplier for area specific acuracy.
Calorific values are the amount of energy available from the fuel per unit. This figure must then be multiplied by the boiler efficiency to get the actual energy delivered.
Also note that there are 2 different boiler efficiencies. When your boiler is serviced the engineer will put a probe into the flue to measure the burner efficiency of the boiler. This is how much of the fuel is combusted. The second efficiency is how much of the burn energy is transferred into the water for use in the home. Both are important but must not be confused.
As the grid becomes less carbon intensive, the calculation for the viability of heat pumps will also change. Countries with high percentages of renewable electricity in their energy mix will get potentially better viability from heat pump technologies. Electricity in the UK has a carbon emission value of 0.517kilogrammes of CO2 per kilowatt (kg/kW) (SAP 2009). This figure is likely to change as the generation mix changes in the future. As the de-carbonisation of the UK grid progresses, so will the viability of heat pumps.
Installation legislation and guidelines have tightened up considerably in recent years with the introduction of the Microgeneration Certification Scheme (MCS). In order to receive any financial incentives, all domestic equipment must be MCS certified and it must also be commissioned by an MCS certified installer in accordance with MIS 3005. This guidance covers the design parameters of the heat pump to cover 99% of the heat load at geographically predetermined minimum ambient temperatures for the location of the installation, factors in the exact specification of the emitters, including pipe size, spacing, flow temperatures and floor surface covering in the case of under-floor heating, ground collector design, including ground conditions, for ground source heat pumps and makes sure that all calculations and potential savings are clearly explained to the customer.
Heat pumps can provide a very effective heat source but in order to maximize the efficiency it is important to make sure that the right specification is made and that the design takes into account all of the project variables. They are not a simple replacement for a boiler and mistakes can be very costly.
The ideal environment for heat Pumps are: A decarbonized Electricity grid, a very well insulated house with a good degree of air-tightness, a moderate amount of thermal mass, a small heat load and a well designed, efficient storage and distribution system. This will potentially allow the heat pump to use the waste heat from the home as a resource, negating the need for an inefficient defrost cycle and allowing the unit to be small enough to run almost continuously. We also need to be very aware of the hot water demand, as this seems to be the biggest problem area for the efficiency of the technology and as the buildings become more efficient it is quite possible that the hot water demand is actually greater than the space heating demand. At this point we would need to re-evaluate the viability of the heat pump, especially air source units. The other big obstacle is the apparent lack of expertise in the industry. If heat pumps are to feature as a viable, renewable heat source then a lot of resource needs to be put into developing an industry to competently support them from design concept to commissioning and end-user operation.